Dear TRNSYS users,
I'm working on a building simulation with type
56.
The bui file was produced with SimCad and the mask file .msk too I have 200 windows in the building, for this reason
I have given
SIMCAD ID numbers to only 36 of them. But the problem is that the .msk file that is
produced (see below) has at the
second and third line more values than the number of the windows with ID number. I suspect (but I am not not sure) that the others values correspond to the others windows without ID numbers. For this reason the second and the third line have
more than 160 characters and
thus cannot be input to IIsiBat in .tpf file How can I solve this problem?
And one more question, related to the specific
application:
In TRNSYS type 68, the third parameter is the
number of surface angles for each opening
How do I choose this parameter? 01 02 03 04 05 06 07 08 09 09 10 11 12 13 14 15 16 17 18 18 19 20 21 22 23 24 25 26 27 27 28 29 30 31 32 33 34 35 36 36 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 73.00 163.00 163.00 73.00 163.00 163.00 163.00 163.00 163.00 163.00 163.00 163.00 -17.00 -17.00 73.00 163.00 163.00 73.00 163.00 163.00 163.00 163.00 163.00 163.00 163.00 163.00 -17.00 -17.00 73.00 163.00 163.00 73.00 163.00 163.00 163.00 163.00 163.00 163.00 -17.00 -17.00 163.00 163.00 163.00 163.00 163.00 163.00 -17.00 -17.00 163.00 163.00 73.00 73.00 163.00 163.00 163.00 163.00 163.00 163.00 73.00 -17.00 73.00 -17.00 163.00 163.00 -17.00 -17.00 -17.00 -17.00 163.00 163.00 163.00 163.00 -107.00 163.00 163.00 -17.00 -17.00 -107.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -107.00 -107.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -107.00 -107.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -107.00 -107.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -17.00 -107.00 -107.00 -180 -162 -144 -126 -108 -90 -72 -54 -36 -18 0 18 36 54 72 90 108 126 144 162 0.00 89.99 89.99...... How can I solve this problem?
And one more question, related to the specific
application:
In TRNSYS type 68, the third parameter is the
number of surface angles for each opening
How do I choose I this parameter? best regards Olympia ____________________________________________________________
Dipl.-Ing. Olympia Zogou
Laboratory of Thermodynamics & Thermal Engines Department of Mechanical & Industrial Engineering University of Thessaly Pedion Areos, 383 34 Volos, Greece Tel. (+3024210) 74013, Fax (+3024210) 74096, E-mail: olyz@xxxxxx http://www.mie.uth.gr/labs/ltte/info/info.htm |