AW: Chilled water system



Hello!

Updating the path to the .bld was the way I used to update the type 56
component in IISiBat too. But I recently discovered the function "update
building variable list" which you can find in the context menu (right
click) of the type 56 component. I was very pleased to find this
function.

Timo



-----Ursprüngliche Nachricht-----
Von: owner-trnsys@xxxxxxxxxxxxxxxxxxx
[mailto:owner-trnsys@xxxxxxxxxxxxxxxxxxx] Im Auftrag von Marc Abadie
Gesendet: Montag, 19. April 2004 13:25
An: trnsys@xxxxxxxxxxxxxxxxxxx
Betreff: Re: Chilled water system


Hi C H,

Each time you modify your .bld file, you just have to "refresh" the path
in type 56 by browsing and finding your .bld file one more time (even if
the path is the same).

-- Marc Abadie, La Rochelle University, France

Choong Chee Hoong a écrit :

> Hi Arie,
>
> Thank you for your reply. I had tried to do that but
> the type 56 didnt update the input. It still do not
> have any new input option in type 56. Do I need to add
> the new input in proforma myself? I tried that too but
> still nothing different. Can you give me some guide
> please?
>
> Thank you.
> C H Choong
>
> --- Arie Kalkman <a.kalkman@xxxxxxx> wrote:
> > Hi Choong Chee Hoong,
> >
> > You need to define a ventilation type in Prebid, and
> > make the air temperature and airchange rate external inputs.
> > Next, connect the Type 32 dry bulb temperature and
> > (air flow / room volume) to your Type 56 inputs...
> > that's all.
> >
> > regards, Arie.
> >
> >
> >
> > -----Oorspronkelijk bericht-----
> > Van:  Choong Chee Hoong [SMTP:sochai9981@xxxxxxxxx]
> > Verzonden:    maandag 19 april 2004 5:45
> > Aan:  trnsys@xxxxxxxxxxxxxxxxxxx
> > Onderwerp:    Chilled water system
> >
> > Dear all,
> >
> > Now I am trying to connect the chilled water system
> > to
> > the multizone building(type 56) but I have no idea
> > how
> > to do it. The multizone building do not have any
> > input
> > option to receive cooled air from the cooling coil.
> > I
> > have attach the my program to this email, can anyone
> > help me to check my program please?
> >
> > My second question is how to link trnsys with
> > matlab?
> > I have downloaded the trnsys-matlab link component
> > from internet but there are some error when i try to
> > run the sample. Can anyone help me on this please?
> >
> > I need to solve this problem quite desperately. I
> > really appreciate if anyone can reply this email as
> > soon as possible.
> >
> > Thank you.
> >
> > C H Choong
> >
> >
> >
> >
> > __________________________________
> > Do you Yahoo!?
> > Yahoo! Photos: High-quality 4x6 digital prints for
> > 25c
> > http://photos.yahoo.com/ph/print_splash << Bestand:
> > New Folder.zip >>
> >
>
>
>
> __________________________________
> Do you Yahoo!?
> Yahoo! Photos: High-quality 4x6 digital prints for 25¢ 
> http://photos.yahoo.com/ph/print_splash