Re: How to Print Input Weather File in Type 25 Using IISibat Option



Dear Arvind,
You can print any output of any TRNSYS component in iisibat by connecting the component that produces the output to a Type25 printer. You may have to add multiple printers and you may have to adjust the number of data values that each printer accepts (by modifying the answer to the question at the bottom of the Type25 "inputs" tab). Most of the standard TRNSYS examples include the Type25 printer. You might take a look at these to see how the printer is hooked up to various other components. Specifically examples 1, 2a, 2b, 3, 5, 6, 7, 8, and 9 use the Type25 printer.
Kind regards,
David



At 01:47 PM 4/21/2004 +0530, you wrote:

Dear Trnsys User,

I would like to print input weather file in output file of Type 25.

In IIsibat only there is option for printing zone output or group of zone
output. But i need to print input weather file also in output file of
Type 25. Is there any option available in IIsibat.

I tried by making changes in dck file but it shouts error, when i run the
simulation. I need ur suggestions.

Regards,
Arvind L Chel(student)
M.Tech. Energy Systems Engg.
IIT Bombay (India)
arvindchel@xxxxxxxxxx
arvindchel@xxxxxxxxxxx




> Maurizio and other TRNSYS users, > >> I receive almost the same error of Choong Chee Hoong when I try to use >> in my simulation type 502 aquastats in heating mode (while the >> simulation run withput any problem when I use type 503 aquastats in >> cooling mode): >> >> ***** ERROR ***** TRNSYS ERROR # 105 >> TYPE502 WAS CALLED IN THE TRNSYS INPUT FILE BUT NOT LINKED. >> A DUMMY TYPE SUBROUTINE WAS CALLED IN ITS PLACE. PLEASE LINK >> TYPE502 BEFORE RUNNING THIS SIMULATION OR TURN OFF THE CHECK >> FOR UNLINKED SUBROUTINES OPTION IN THE CONFIGURATION FILE. > > TRNSYS Error 105 is a generic error. It tells you that a TRNSYS > component (Type) is not actually present in the TRNSYS version you are > using for your simulation. > TRNSYS consists of 2 main parts: > - an executable program (trnsys.exe), which is the visual front-end that > displays the online plotter > - Trnlib.dll, a dynamic-linked library (DLL) that includes the TRNSYS > kernel (equation solver) and the components ("TYPEs") > > The default component library (Trnlib.dll) only has the standard > components (the ones listed in the TRNSYS manual, e.g. TYPEs 1, 2, 9, > 16, 89, 24, 25, 65, etc.). If you want to use other components, you need > to add them to your component library by LINKING them with other > components and the kernel into trnlib.dll. This is done using a Fortran > compiler. Note that your TRNSYS distributor can do that for you if you > purchase additional components for them. > > > About TRNSYS Error 105 (Type xxx was not linked) > ------------------------------------------------ > > If you are getting this error while using the standard TRNSYS components > (the ones listed in the TRNSYS manual, e.g. Types 1, 2, 16, 9, 89, > etc.), you probably have a problem with your TRNSYS installation and you > should reinstall the program. > > If you are getting that error with some components that are part of an > optional library which you purchased from your TRNSYS distributor (e.g. > TESS libraries or TRANSSOLAR non-standard components), you should > contact your distributor to get a correct version of Trnlib.dll > > If you are getting this error while trying to use one of the components > that can be found in the "TRNLIB" section of the website or a component > provided to you by another user, you need to "rebuild" trnlib.dll in > order to add those components to TRNSYS. Please refer to the TRNSYS > manual or to the "Fortran info" section of the TRNSYS website for more > information. > > > > Kind regards, > > Michaël Kummert > > > -- > _________________________________________________________ > > Michaël Kummert > > Solar Energy Laboratory - University of Wisconsin-Madison > 1303 Engr Res Bldg, 1500 Engineering Drive > Madison, WI 53706 > > Tel: +1 (608) 263-1589 > Fax: +1 (608) 262-8464 > E-mail: kummert@xxxxxxxxxxxxx > > SEL Web Site: http://sel.me.wisc.edu > TRNSYS Web Site: http://sel.me.wisc.edu/trnsys > >

**************************************************************************************** Thermal Energy System Specialists (TESS) David BRADLEY 2916 Marketplace Drive - Suite 104 Partner Madison, WI 53719 Phone: (608) 274-2577 USA Fax: (608) 278-1475 E-mail: bradley@xxxxxxxxxxxx Web Pages: http://www.tess-inc.com and http://www.trnsys.com