Catherine,
Is there a component available for modelling desiccant cooling?
Some components are available as part of TRNLib, the library of
user-contributed components.
You can find them on our website:
http://sel.me.wisc.edu/trnsys
Go to "TRNLIB", then "Additional categories", then "desiccants"
The direct link is:
http://sel.me.wisc.edu/trnsys/trnlib/dessi.htm
A recent MS Student at the lab also studied rotary enthalpy exchanger
and he developed a component, which is available at the SEL (just send
me an email). The MS thesis is available online:
http://sel.me.wisc.edu/theses/freund03.zip
You have to realize that those components are not part of the standard
package, hence they are not supported by TRNSYS distributors. You will
also need a compiler to add them to your TRNSYS DLL.
If you need a better supported / more convenient option, you should
contact TESS (Thermal Energy Systems Specialists - www.tess-inc.com).
They are currently working on expanded component libraries, which will
include desiccant cooling. You may be able to get one component before
the official release of the new libraries. Those components come with
full support and your distributor will generate a DLL for you.
Kind regards,
Michaël Kummert
--
_________________________________________________________
Michaël Kummert
Solar Energy Laboratory - University of Wisconsin-Madison
1303 Engr Res Bldg, 1500 Engineering Drive
Madison, WI 53706
Tel: +1 (608) 263-1589
Fax: +1 (608) 262-8464
E-mail: kummert@xxxxxxxxxxxxx
SEL Web Site: http://sel.me.wisc.edu
TRNSYS Web Site: http://sel.me.wisc.edu/trnsys