Dear TRNSYS
users, I am optimizing 7 variables
of a thermosyphon solar system and during some iteration I get a run time error
as shown in the figure attached. It appears as though a square root of a
negative number is trying to be calculated. The input values that are being
optimized are lower and upper bound, so that irrational values are not
simulated. I haven’t recompiled trnlib.dll. The only thing I did was
install the trnsys_15_3_00_p01.exe patch. I would like to know if this
occurrence is inevitable or if there is anything I can do to avoid it. Best regards, Juan Pablo de L. C. Salazar -- Esta mensagem foi verificada pelo sistema de antivírus e acredita-se estar livre de perigo. |
Attachment:
TRNSYS ERROR.JPG
Description: JPEG image