Dear TRNSYS users,

 

I am optimizing 7 variables of a thermosyphon solar system and during some iteration I get a run time error as shown in the figure attached. It appears as though a square root of a negative number is trying to be calculated.  The input values that are being optimized are lower and upper bound, so that irrational values are not simulated. I haven’t recompiled trnlib.dll. The only thing I did was install the trnsys_15_3_00_p01.exe patch. I would like to know if this occurrence is inevitable or if there is anything I can do to avoid it.

 

Best regards,

Juan Pablo de L. C. Salazar

 

 


--