[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] Re: TYPE55 periodic integrator



At 01:52 PM 11/3/2004 +0100, you wrote:

I simulate a system with a simulation time step of 1 minute. I would like to
use TYPE 55 "periodic integrator" to obtain mean temperatures over a period
of 3 minutes.
The values of the parameters for one input are written below :

- Integrate or sum input 1 : -1 (sum)
- Relative starting hour for input 1 : 1 hr
- Duration for input 1 : 3 min
- Cycle repeat time for input 1 : 3 min
- Reset time for input 1 : 3 min
- Absolute starting hour for input 1 : 1 hr
- Absolute stopping hour for input 1 : 744 hr

It doesn't work correctly and I do not understand why. I think the problem
comes from the "relative starting hour". I tried 1 hr, 0 hr, 3 min without
success.

Are you using a later version of the TRNSYS 15 software? I just tried the following example and it worked perfectly:


ASSIGN ***.LST  6
ASSIGN ***.OUT  21

EQUATIONS 2
STEP=1/60
RESET=3/60

SIMULATION 1 100  STEP

EQUATIONS 1
A=TIME

UNIT 55 TYPE 55 PERIODIC INTEGRATOR
PARAMETERS 7
1  1  RESET  RESET  RESET  1  8760
INPUTS 1
A
0.0

UNIT 25 TYPE 25 PRINTER
PARAMETERS 5
RESET  1  8760  21  1
INPUTS 2
55,3  55,2
MEAN  COUNT
-  -

END

Results:

TIME            MEAN            COUNT
[HR]            [-]             [-]
+1.00000E+00    +0.00000E+00    +0.00000E+00
+1.05000E+00    +1.03333E+00    +3.00000E+00
+1.10000E+00    +1.08333E+00    +3.00000E+00
+1.15000E+00    +1.13333E+00    +3.00000E+00
+1.20000E+00    +1.18333E+00    +3.00000E+00
+1.25000E+00    +1.23333E+00    +3.00000E+00
+1.30000E+00    +1.28333E+00    +3.00000E+00
+1.35000E+00    +1.33333E+00    +3.00000E+00
+1.40000E+00    +1.38333E+00    +3.00000E+00
+1.45000E+00    +1.43333E+00    +3.00000E+00
+1.50000E+00    +1.48333E+00    +3.00000E+00
+1.55000E+00    +1.53333E+00    +3.00000E+00
+1.60000E+00    +1.58333E+00    +3.00000E+00
+1.65000E+00    +1.63333E+00    +3.00000E+00
+1.70000E+00    +1.68333E+00    +3.00000E+00
+1.75000E+00    +1.73333E+00    +3.00000E+00
+1.80000E+00    +1.78333E+00    +3.00000E+00
+1.85000E+00    +1.83333E+00    +3.00000E+00
+1.90000E+00    +1.88333E+00    +3.00000E+00
+1.95000E+00    +1.93333E+00    +3.00000E+00
+2.00000E+00    +1.98333E+00    +3.00000E+00
+2.05000E+00    +2.03333E+00    +3.00000E+00
+2.10000E+00    +2.08333E+00    +3.00000E+00
+2.15000E+00    +2.13333E+00    +3.00000E+00
+2.20000E+00    +2.18333E+00    +3.00000E+00
etc.


Jeff


********************************************************************************* Thermal Energy System Specialists (TESS) Jeff Thornton 2916 Marketplace Drive Principal Suite 104 Phone: (608) 274-2577 Madison WI 53719 Fax: (608) 278-1475 USA E-mail: thornton@xxxxxxxxxxxx Web Page: www.tess-inc.com

"Providing software solutions for today's energy engineering projects"
*********************************************************************************

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@xxxxxxxxxxxxx
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users