[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: sensitivity analysis



Hello,
I'm doing sensitivity analysises in the same way as Hilde (with Matlab), if you want an example of the matlab-file, I can send it to you, Beatriz.
But I also ran into a problem:
I want to use my data-files from type 25 as an input in my next run of trnsys, but there is always a header line in the type25-files.  This data file is 8760 houres, i.e. one year long. I don't have any problems when my simulation is one year aswell; I just let the data reader skip the first line. But when I want to run more years in a row, the data reader doesn't skip the first row anymore and an error is produced.
Does somebody know how I can get rid of the header line in trnsys ? or how to skip the header line when the second year is started ?
And something else, does somebody know how to put TRNSYS the whole in time in low priority, i.e. before it starts running ? Everytime it restarts for the analysis, I have to open the task manager and do it again.

Best regards,
Jeroen

Hilde Breesch wrote:
Dear Beatriz,
 
I'm working on a sensitivity analysis too (to identify which parameters have the greatest impact on thermal summer comfort in a building that is cooled by natural night cooling). I control the simulation process in Matlab to prepare the input files for Prebid and Trnsys and to run these programs too.
 
to run Prebid from an other program:
rename prebid.exe bid.exe and use command line:
\Trnsys15\prebid\bid.exe name_of_file.bui
 
to run Trnsys:
\Trnsys15\\trnsys.exe name_of_file.dck /n
 
If you have more questions, you can send me an e-mail directly.
 
best regards,
 
Hilde Breesch
PhD student Buildings & Climatic Control
Ghent University, Department of Architecture & Urban Planning
Plateaustraat 22, B-9000 GENT
tel. +32 9 264 78 61  fax. +32 9 264 41 85
e-mail: Hilde.Breesch@xxxxxxxx
http://allserv.ugent.be/~hbreesch/research
----- Original Message -----
Sent: Monday, May 03, 2004 4:01 PM
Subject: sensitivity analysis

Dear TRNSYS users,

I am trying to perform a sensitivity analysis to identify the parameter to which indoor air Tª  is most sensitive. I am specially interested in a number of particular parameters. Is there any capability implemented in TRNSYS, which could help to develop this kind of analysis.

Thanks a lot in advance.

Best regards, Beatriz.

-----------------------------

Beatriz Porcar Laynez

Bioclimatic Architecture Programme

Renewable Energy Department

CIEMAT (Centro de Investigaciones Energéticas Medioambientales y Tecnológicas)

mailto: beatriz.porcar@xxxxxxxxx

Phone: (+34) 913466344

Mobil phone: 628271620

-------------------------------