[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: AW: humidity calculation
- Date: Tue, 17 Sep 2002 07:55:19 -0500
- Date: Tue, 17 Sep 2002 06:59:14 -0600
- From: David Bradley <bradley@xxxxxxxxxxxx>
- Subject: Re: AW: humidity calculation
Bengt,
I also have a very basic qyestion how the humidity ratio ie. 50% rel
humidity should be given in the TMY weather files as 50% ? or as the decimal
0.5 ?. I get TRNSYS errors/warnings when RH is given in %
The humidity in a TRNSYS TMY weather file (like \trnsys15\weather\madisn.wi) should be given as kgH2O/kgdryair * 10000, so a humidity ratio instead of a relative humidity. In terms of outputs, Type89 reports relative humidity in %.
Cheers,
David
*********************************************************************************
Thermal Energy System Specialists (TESS)
David BRADLEY 2916 Marketplace Drive - Suite 104
Project Engineer Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Page: www.tess-inc.com
"Providing software solutions for today's energy engineering projects"
**************************************************************************** *****