[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: run alltrn32.bat (version 14.2)



Gilles,
The param.inc file (in TRNSYS 14) was located in the \trnwin\kernal directory. It was moved with the release of TRNSYS 15 to the \trnsys15\include directory. If you have TRNSYS 14.2 installed in its \trnwin directory then all the TRNSYS 14 source code files should point to the correct location. You can check by opening the code and verifying that the line:

INCLUDE '../kernal/param.inc'

exists and that param.inc is indeed inside the kernal directory.

Kind regards,
David


At 06:38 PM 12/2/2003 +0100, Gilles Fraisse wrote:

hello trnsys users ,
after several problems I have had to install trnsys 14.2 again. When I use rebuild (before using new TYPEs), I have the error "can not open include file param.inc" for many fortran programs (hplot ...) which are already installed in TRNSYS. Where can I indicate the location of param.inc for all these fortran programs ?
thanks for any help
Gilles






°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°
Gilles FRAISSE
LOCIE - Equipe Génie Civil et Habitat
Ecole Supérieure d'Ingenieurs de Chambéry (ESIGEC)
Campus Scientifique Savoie Technolac
Université de Savoie - 73376 - Le Bourget du Lac Cedex (France)
Téléphone +33 (0)4 79 75 88 95
Télécopie +33 (0)4 79 75 81 44
°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°
****************************************************************************************
Thermal Energy System Specialists (TESS)
David BRADLEY                           2916 Marketplace Drive - Suite 104
Project Engineer                           Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com