[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: isibat 3
- Date: Mon, 19 Apr 2004 08:58:45 -0500
- From: Michaël Kummert <kummert@xxxxxxxxxxxxx>
- Subject: Re: isibat 3
...
> I have a problem when running a simulation from isibat 3, I got two
identical errors:
TRNSYS ERROR # 172
UNIT 4 TYPE 16 RADIATION PROCESSOR
TIME INCONSISTENCY BETWEEN WEATHER AND RADIATION PROCESSOR
BE SURE THAT THE WEATHER DATA READER OR WEATHER DATA
GENERATOR PRECEDES THIS UNIT OF TYPE 16 IN THE INPUT FILE.
and I have no idea of how to solve it.
I use to solve that error in PRESIM renumbering the components so that the
data reader was before the radiator processor, but I don´t know how to do this
in ISIBAT 3. In this case this is not my problem, because in the deck file the
radiator processor is after, though not immediately after.
The way to re-order components in IISiBat is to go to "control cards"
(assembly/control cards, or the "document icon") and to select the
component order tab.
If that is not the problem, please make sure that you connected the
"time of last data read" and "time of next data read" inputs. Failure to
do so will give that error.
I have also other doubts:
How can I include units in my non-format data readers? How can I include
the "Inext" values of radiation in this readers? I used to do it in PRESIM
modifying an existing one, but I have no examples of data readers of this type.
I am not sure I understand your problem, but all data readers output the
values at next (data) time step (outputs 101 and above).
Kind regards,
Michaël Kummert
--
_________________________________________________________
Michaël Kummert
Solar Energy Laboratory - University of Wisconsin-Madison
1303 Engr Res Bldg, 1500 Engineering Drive
Madison, WI 53706
Tel: +1 (608) 263-1589
Fax: +1 (608) 262-8464
E-mail: kummert@xxxxxxxxxxxxx
SEL Web Site: http://sel.me.wisc.edu
TRNSYS Web Site: http://sel.me.wisc.edu/trnsys