The order of the types in a simulation can be changed in Isibat by clicking on the "global info" button (the letter-like icon) on the left. On the "Component Order" Sheet (the last one behind the control card) you can find the order of the types. From my own experience it's best that the radiation processor is right after the weather data reader. Check also the "starting day" parameter in type 16. It should be the same as the start time of the simulation (in the global info control card).


Fernando Varela Díez wrote:

My name is Fernando Varela, and I´m a doctorate student in Valladolid (Spain).I have a problem when running a simulation from isibat 3, I got two identical errors:

TRNSYS ERROR # 172
UNIT 4 TYPE 16 RADIATION PROCESSOR
TIME INCONSISTENCY BETWEEN WEATHER AND RADIATION PROCESSOR BE SURE THAT THE WEATHER DATA READER OR WEATHER DATA GENERATOR PRECEDES THIS UNIT OF TYPE 16 IN THE INPUT FILE.


and I have no idea of how to solve it.

I use to solve that error in PRESIM renumbering the components so that the data reader was before the radiator processor, but I don´t know how to do this in ISIBAT 3. In this case this is not my problem, because in the deck file the radiator processor is after, though not immediately after.

I have also other doubts:

How can I include units in my non-format data readers? How can I include the "Inext" values of radiation in this readers? I used to do it in PRESIM modifying an existing one, but I have no examples of data readers of this type.


Thank you very much.