Thomaz,
The easiest way to use more than one Type45 in a simulation is to make a copy of Type45.for and rename it with another Type number (Type145.for for example). You will have to modify the code as well - any mention of "45" will have to be given the new number "145." Also, any internal subroutines in Type45 will need to be renamed. Type45 calls Type1 and Type38 I melieve. You do not need to make copies of those subroutines.
Cheers,
David
At 11:31 PM 8/2/01 -0300, you wrote:
>Hi,
>Are there a manner to use two type 45 units in one TRNSYS simulation
>code?
>
>I need to simulate 2 types of thermosyphon solar water heating systems
>simultaneously. In a first try, this message appeared:
>
>TRNSYS ERROR 103 Maximum number of type 45 components exceeded
>
>Does anyone have sugestions to solve this problem?
>
>Thanks in advance!
>
>Thomaz Borges
>Solar Energy Reseacher - Brazil
>