Re: Desire to use two type 45 units....



Dear David,

I forgot to thank you for your help in my problem with two type 45 units in one simulation code.

Thank you!

Regards from Brazil,

Thomaz

David Bradley wrote:

Thomaz,
        The easiest way to use more than one Type45 in a simulation is to make a copy of Type45.for and rename it with another Type number (Type145.for for example). You will have to modify the code as well - any mention of "45" will have to be given the new number "145." Also, any internal subroutines in Type45 will need to be renamed. Type45 calls Type1 and Type38 I melieve. You do not need to make copies of those subroutines.
Cheers,
        David

At 11:31 PM 8/2/01 -0300, you wrote:
>Hi,
>Are there a manner to use two type 45 units in one TRNSYS simulation
>code?
>
>I need to simulate 2 types of thermosyphon solar water heating systems
>simultaneously.  In a first try, this message appeared:
>
>TRNSYS ERROR 103 Maximum number of type 45 components exceeded
>
>Does anyone have sugestions to solve this problem?
>
>Thanks in advance!
>
>Thomaz Borges
>Solar Energy Reseacher - Brazil
>

--
***************************************************
THOMAZ BORGES
Eng. Mecânico, Dr.

tel (019) 3287-4619
cel (019)9604-5765
thomazborges@bestway.com.br
http://www.bestway.com.br/~luzdosol
***************************************************
 

begin:vcard 
n:Borges;Thomaz Borges
tel;cell:(0xx19) 9604-5765
tel;fax:55-19-3287-4619
tel;work:55-19-3287-4619
x-mozilla-html:TRUE
url:http://www.bestway.com.br/~luzdosol
org:Energia em Edificações - Soluções Renováveis
adr:;;;Campinas;SP;;Brazil
version:2.1
email;internet:thomazborges@bestway.unicamp.br
title:Eng. Mecânico, Dr.
fn:Thomaz Borges
end:vcard