Re: detailed flat plate collector model



see the attached file ("excel" file).
It is a steady state model with 1 cover.
It's important to do the "iterations" (line 33 to 32).
I 've done a "TRNSYS dynamical model" but I have no "word paper" describing
the model. I m looking for experimentations (with flow variations : on-off
variations for exemple) to continue the validation of the model. 
see you later ,
Gilles Fraisse


At 14:08 04/06/02 +0200, you wrote:
>Dear trnsys users,
>
>I'm looking for a detailed flat plate collector model. The aim is to obtain,
>as OUTPUT, the different collector losses :
>
>- backside heat losses (conduction through insulating material) ;
>- topside convection heat losses ;
>- topside radiation heat losses ;
>- optical reflexion from the cover to the surrounding.
>
>If somebody knows such a model, I'm very interrested to get the detailed
>description (mathematical description, inputs, parameters, outputs,...) and
>the source code perhaps.
>
>Thanks for your help,
>Christophe.
> 

Attachment: capsolai.xls
Description: MS-Excel spreadsheet

      

    

     

°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°° 

Gilles FRAISSE  

Laboratoire Génie Civil et Habitat 

Ecole Supérieure d'Ingenieurs de Chambéry (ESIGEC) 

Campus Scientifique Savoie Technolac 

Université de Savoie - 73376 - Le Bourget du Lac Cedex (France) 

Téléphone +33 (0)4 79 75 88 95 

Télécopie +33 (0)4 79 75 81 12 

°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°