see the attached file ("excel" file). It is a steady state model with 1 cover. It's important to do the "iterations" (line 33 to 32). I 've done a "TRNSYS dynamical model" but I have no "word paper" describing the model. I m looking for experimentations (with flow variations : on-off variations for exemple) to continue the validation of the model. see you later , Gilles Fraisse At 14:08 04/06/02 +0200, you wrote: >Dear trnsys users, > >I'm looking for a detailed flat plate collector model. The aim is to obtain, >as OUTPUT, the different collector losses : > >- backside heat losses (conduction through insulating material) ; >- topside convection heat losses ; >- topside radiation heat losses ; >- optical reflexion from the cover to the surrounding. > >If somebody knows such a model, I'm very interrested to get the detailed >description (mathematical description, inputs, parameters, outputs,...) and >the source code perhaps. > >Thanks for your help, >Christophe. >
Attachment:
capsolai.xls
Description: MS-Excel spreadsheet
°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°° Gilles FRAISSE Laboratoire Génie Civil et Habitat Ecole Supérieure d'Ingenieurs de Chambéry (ESIGEC) Campus Scientifique Savoie Technolac Université de Savoie - 73376 - Le Bourget du Lac Cedex (France) Téléphone +33 (0)4 79 75 88 95 Télécopie +33 (0)4 79 75 81 12 °°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°