[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

AW: Edge effects windows.



Hello Maurice,

the problem might be caused by your spacer u-value if it is similar to you glass ther will be no difference.
Did you check also with specer id 1 : Aluminum - ASHREA Metallic : using width an hight in prebid.
for a very good glasing you should see quite a difference. 

with kind regards,

your TRNSYS Hotline Team

T.Welfonder, M.Rudolph


Mailto:Hotline@transsolar.com; http://www.transsolar.com
--------------------------------------------------------------------------------------------------------------------
TRNSYS - course 1 :	Introduction into the work with TRNSYS
Basics for dynamic simulations
generating systems with IISiBat (solar system for domestic hot water) 
10. + 11. November 2003
Price:	_ 900,- per person, + VAT
--------------------------------------------------------------------------------------------------------------------
TRNSYS - course 2 :	Building Simulations with TRNSYS
Input of  building data in PREBID
Modelling of heating, cooling and control systems in IISIBAT
how to do checking of  the results
(for experienced TRNSYS-users, or participants of course 1)
26. +  27. November 2003
Price:	_ 900,- per person, + VAT
--------------------------------------------------------------------------------------------------------------------
TRNSYS - course 4 :	airflow simulation in buildings TRNFLOW
Theory and Basics
introduction into the module TRNFLOW
Integration of TRNFlow in TRNSYS 15
available TRNFlow airflow components 
Outputs of TRNFLOW
Example 
adding the different TRNFLOW components to an  existing multi zone model of a office with double fassade
changes in the TRNSYS input file for TRNFLOW simulations
making different simulation
hints  and checking of the results
(for experienced TRNSYS-users, or participants of course 2)
28. November 2003
Price:	_ 650,- per person, + VAT
--------------------------------------------------------------------------------------------------------------------
Information about TRNFLOW can be found at: http://www.transsolar.com/ts/indexflo.htm.
if you need any further information please contact hotline@transsolar.com.





-----Ursprüngliche Nachricht-----
Von: Jong, M.J.M. [mailto:jong@ecn.nl] 
Gesendet: Dienstag, 28. Oktober 2003 14:44
An: TRNSYS E-mail group (E-mail)
Betreff: Edge effects windows.


Dear TRNSYS users,

At the moment I am simulating an old office building. The office building is provided with a lot of windows with frames seperated by dividers (in one frame, there are many little windows). At the moment, the building is provided with single pane glazing. To reduce the amount of energy for room heating, a possibility is to provide the windows with double glazing. A disadvantage of a window with a frame that is provided with dividers is that the edge effect of the glazing has a great influence on the total U value of the window. I tried to simulate this effect in TRNSYS 15.3.

First I made a simple 4 zones box model. The dimensions of every zone are 2 x 2 x 2  m. In one external wall in every zone there is a window of 1 m2, with 21.6 % frame area. The total annual heating demand of this box is 5.21 GJ/year.

For the second simulation, I modified the model to a model with in every external wall 4 windows of 0.25 m2. In the first model I had an external wall of 4 m2 with 1 m2 window in it. In the second model, I have 4 externall walls of 0.5 m2 each with a window of 0.25 m2 in each wall. The frame area is again 21.6 %. I defined both windows myself with the help of Window 4.1. In window 4.1 I chose for a custom size and for the window in my first simulation I had the dimensions of 1000 x 1000 mm (width of frame is 57.15 mm). The dimensions of the window in my second simulation were 500 x 500 mm (width of the frame is 28.575 mm). The frame area of 4 windows of 500 x 500 mm is exactly the same as the frame area of a window of 1000 x 1000 mm. In both simulation I chose in the windows menu for ID-spacer option 0 (data from W4lib.dat). Also in this case the total annual heating demand was 5.21 GJ/year. To be exact, the difference in the annual heating demands was 0.00155 GJ/year. I thi!
 nk this is impossible. The heating demand of the model with windows of 500 x 500 mm must be significant higher. Does anybody has experience with the influence of the edge effects of windows on the heating demand in TRNSYS ?  

Analysing the W4lib.dat file I found something that I do not understand. For every window in the library, you can see values as shown below. As I interpretate the numbers will, you have for 4 temperatures (-17.8, 15.6, 26.7 and 37.8 °C) the overall and the Center of Glass U-value of the window. For every window in the library, these 2 U-values are exactly the same. I think there must be a difference between these 2 U-values. The overall U-value must be higher than the Centre of Glass value. Is this correct ?

Overall and Center of Glass Ig U-values (W/m2-C)
Outdoor Temperature                 -17.8 C      15.6 C      26.7 C
37.8 C
Solar      WdSpd  hcout hrout  hin
(W/m2)     (m/s)     (W/m2-C)
   0        0.00  12.25  3.24  7.59  1.44 1.44  1.35 1.35  1.38 1.38  1.45
1.45 
   0        6.71  25.47  3.21  7.62  1.51 1.51  1.39 1.39  1.43 1.43  1.51
1.51 
 783        0.00  12.25  3.41  6.82  1.41 1.41  1.42 1.42  1.47 1.47  1.53
1.53 
 783        6.71  25.47  3.31  7.10  1.51 1.51  1.45 1.45  1.51 1.51  1.56
1.56 

With kind regards,


Maurice Jong.

============================================================================
======

Maurice Jong
ECN - Energy research Centre of the Netherlands		Department: DEGO
P.O. Box 1    1755 ZG  Petten				Country:   The
Netherlands
Telephone:    +31 (0)224 564938				Fax:       +31
(0)224 568966
E-mail: jong@ecn.nl					Internet: