on 2003-11-10 19:31, Fardin wrote:

hi and thanks for your quick respond what i wanna know more is: could be possible to make algebraic tank (type 38) in small size for exampel (400-600 Lit)?
thanks



All tank models in TRNSYS are suitable for such volumes. Actually, there is no limitation on the volume itself. The risk is that a given combination of volume, number of nodes, time step, flowrate, etc. would lead to numerical instabilities. But 400-600 liters should work fine with usual conditions and settings.