[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] parametric run



Thanks a lot Michaël , Werner and Walter for all these explanations. Parametric run is really a great tool.

Kind regards,

Isabelle


A 09:31 23/09/2004 -0500, Michaël Kummert a écrit :
Isabelle,

Does that mean that I can have only one printing file, and so maximum 10 outputs for parametric runs ?

Each printer can actually print 30 variables, but you can have more than
one printer (up to 4 per simulation) using numbered files in parametric
runs. The extension does not need to be ".out", so you can for example have:

MyDeck.dck
- Reads MyWeather.tm2 (same for all runs)
- Uses MyBuilding.bld,trn (same for all runs)
- Prints to MyDeck.ou1, MyDeck.ou2, MyDeck.ou3, MyDeck.txt, etc.
  (numbered with runs)

Kind regards,

Michaël Kummert


--
_________________________________________________________

Michaël Kummert

Solar Energy Laboratory - University of Wisconsin-Madison
1303 Engr Res Bldg, 1500 Engineering Drive
Madison, WI 53706

Tel: +1 (608) 263-1589
Fax: +1 (608) 262-8464
E-mail: kummert@xxxxxxxxxxxxx

SEL Web Site: http://sel.me.wisc.edu
TRNSYS Web Site: http://sel.me.wisc.edu/trnsys

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@xxxxxxxxxxxxx
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

Isabelle Bruyère                                                
Université Catholique de Louvain                        Place du Levant, 1 à 1348 Louvain-la-Neuve
Unité d'architecture - Architecture et Climat           Tél : 010/47 21 38 - Fax : 010/47 21 50

http://www-climat.arch.ucl.ac.be/